﻿<?xml version="1.0" encoding="UTF-8" ?><document><webSite>www.bileita.com</webSite><updatePen>1440</updatePen><item><title>避雷塔_GH环形钢管避雷塔</title><link>http://www.bileita.com/tieta/bileita_gh.htm</link><description>避雷塔,GH环形钢管避雷塔,避雷塔-GH-12m避雷针,避雷塔-GH-25m避雷针,避雷塔-GH-19m避雷针</description><text>避雷塔-GH-19m避雷针   避雷塔-GH-25m避雷针             避雷塔-GH-12m避雷针</text><image>http://www.bileita.com/up_files/bileita_gh1.jpg</image><keywords>钢管避雷塔,避雷针,避雷塔,GH环形钢管避雷塔</keywords><category>铁塔产品列表</category><author>GH环形钢管避雷塔</author><source>避雷塔</source><pubDate>2011-02-15 10:19</pubDate></item><item><title>避雷塔_GJT避雷塔_GJT系列避雷塔</title><link>http://www.bileita.com/tieta/bileita_gjt.htm</link><description>避雷塔,GJT避雷塔,GJT系列避雷塔</description><text>避雷塔-GJT-15m避雷针      避雷塔-GJT-20m避雷针                避雷塔-GJT-25m避雷针      避雷塔-GJT-30m避雷针                  避雷塔-GJT-35m避雷针      避雷塔-GJT-40m避雷针</text><image>http://www.bileita.com/up_files/bileita_gjt1.jpg</image><keywords>避雷塔,GJT避雷塔,GJT系列避雷塔</keywords><category>铁塔产品列表</category><author>GJT系列避雷塔</author><source>避雷塔</source><pubDate>2011-02-15 10:10</pubDate></item><item><title>避雷塔_GFW避雷塔_GFW系列避雷塔</title><link>http://www.bileita.com/tieta/bileita_gfw.htm</link><description>避雷塔技术参数_GFW避雷塔_GFW系列避雷塔,GFW（1-2）-40m避雷针</description><text>技术参数    一、GFW1-20米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFW2-20米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度              技术参数    一、GFW1-25米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFW2-25米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度         GFW（1-2）-20m避雷针   GFW（1-2）-25m避雷针            技术参数    一、GFW1-30米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFW2-30米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度              技术参数    一、GFW1-35米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFW2-35米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度         GFW（1-2）-30m避雷针   GFW（1-2）-35m避雷针            技术参数    一、GFW1-40米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFW2-40米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度              技术参数    一、GFW1-45米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFW2-45米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度         GFW（1-2）-40m避雷针   GFW（1-2）-45m避雷针</text><image>http://www.bileita.com/up_files/bileita_gfw1.jpg</image><keywords>避雷针,避雷塔,GFW避雷塔,GFW系列避雷塔</keywords><category>铁塔产品列表</category><author>GFW系列避雷塔</author><source>避雷塔</source><pubDate>2011-02-15 10:00</pubDate></item><item><title>避雷塔_GFL避雷塔_GFL系列避雷塔</title><link>http://www.bileita.com/tieta/bileita_gfl.htm</link><description>避雷塔技术参数,GFL避雷塔,GFL系列避雷塔,GFL（1-2）-20m避雷针</description><text>技术参数    一、GFL1-20米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFL2-20米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度              技术参数    一、GFL1-25米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFL2-25米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度         GFL（1-2）-20m避雷针   GFL（1-2）-25m避雷针            技术参数    一、GFL1-30米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFL2-30米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度              技术参数    一、GFL1-35米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFL2-35米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度         GFL（1-2）-30m避雷针   GFL（1-2）-35m避雷针            技术参数    一、GFL1-40米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFL2-40米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度              技术参数    一、GFL1-45米    1. 设计风压：0.4KN/M2   2. 抗震烈度：7度    二、GFL2-45米    1. 设计风压：0.7KN/M2   2. 抗震烈度：8度         GFL（1-2）-40m避雷针   GFL（1-2）-45m避雷针</text><image>http://www.bileita.com/up_files/bileita_gfl1.jpg</image><keywords>避雷针,避雷塔,GFL避雷塔,GFL系列避雷塔</keywords><category>铁塔产品列表</category><author>GFL避雷塔</author><source>避雷塔</source><pubDate>2011-02-15 09:46</pubDate></item><item><title>避雷引线和变电室接地干线敷设安装施工工艺标准</title><link>http://www.bileita.com/news/18.htm</link><description>避雷引线和变电室接地干线敷设安装施工工艺标准

</description><text>避雷引线和变电室接地干线敷设安装施工工艺标准（QB-CNCEC J060304-2004）1 适用范围本工艺标准适用于一般工业与民用建筑防雷接地工程及变配电室接地干线安装工程。2 施工准备2.1 原材料、半成品的要求2.1.1 品种规格2.1.1.1 主要材料：镀锌钢材有扁钢、圆钢、铜材等接地材料。2.1.1.2 其他材料：电焊条、氧气、乙炔、支架、小线、螺栓、黄色油漆、绿色油漆等。2.1.2 质量要求 镀锌钢材应根据设计要求选用冷镀锌或热镀锌材料，材料应有材质检验证明及产品出厂合格证。2.2 主要工机具常用电工工具、钢锯、电焊机、切割机、压力案子、卷尺、电锤、冲击钻、电焊工具等。2.3 作业条件2.3.1 避雷引下线暗敷设作业条件2.3.1.1 建筑物（或构筑物）有脚手架或爬梯，达到能上人操作条件。2.3.1.2 利用主筋作引下线时，钢筋绑扎完毕。2.3.2 避雷引下线明敷设作业条件2.3.2.1 支架安装完毕。2.3.2.2 建筑物（或构筑物）有脚手架或爬梯，达到能上人操作条件。2.3.2.3 土建外装修完毕。2.4 作业人员主要施工人员：电工、油工。经过培训考核持证上岗。3.2 操作工艺3.2.1 避雷引下线暗敷设3.2.1.1 首先将所用扁钢（或圆钢）用手锤等进行调直或抻直。3.2.1.2 将调直的引下线运到安装地点，按设计要求随建筑物引上，挂好。3.2.1.3 及时将引下线的下端与接地体焊接好，或与接地卡子连接好。随着建筑物的逐步增高，将引下线埋设于建筑物内至屋顶为止。如需接头则需进行焊接，焊接后应敲掉药皮并刷防锈漆（现浇混凝土除外）并请有关人员进行隐检验收，做好记录。3.2.1.4 利用主筋（直径不小于16mm）作引下线时，应按设计要求找出全部主筋位置，用油漆作好标记，设计无要求时应于距室外地面0.5m处焊好测试点，随钢筋逐层串联焊接至顶层，各层搭接长度为圆钢直径的6倍，并要求双面施焊。焊接出一定长度的引下线，搭接长度不小于100mm，做完后请有关人员进行隐检，做好隐检记录。3.2.2 避雷引下线明敷设3.2.2.1 引下线如为扁钢，可放在平板上用手锤调直；如为圆钢最好选用直条，如为盘条则需将圆钢放开，用倒链等进行冷拉直。3.2.2.2 将调直的引下线搬运到安装地点。3.2.2.3 自建筑物上方向下逐点固定，直到安装断接卡子处，如需接头或焊接断接卡子，则应进行焊接，焊好后清除药皮，局部调直并刷防锈漆。3.2.2.4 将引下线地面上2m段套上保护管，卡接固定并刷红白油漆。3.2.2.5 用镀锌螺栓将断接卡子与接地体连接牢固。3.2.3 变配电室接地干线敷设3.2.3.1 如果为砖墙（或加气混凝土墙、空心砖墙）则应根据设计要求，确定坐标轴线位置，然后随砌墙将事先预制好的50mm50mm方木样板放入墙内，待墙砌好后将方木样板剔出，将支持架放入孔中，同时撒水淋湿孔洞，再用水泥砂浆将支持件埋牢，待凝固后使用。如果在现浇混凝土上固定支架，先根据图纸要求弹线定位，钻孔，支持架做燕尾埋入孔中，找平找正，用水泥砂浆进行固定。3.2.3.2 支持件埋设完毕后，可敷设接地干线。将接地干线沿墙吊起，在支持件一端用卡子将扁钢固定，经过隔墙时穿跨顶留孔，接地干线连接处应焊接牢固。末端预留或连接应符合设计要求。3.2.3.3 于接地干线外表 面刷黄绿相间油漆标识。4 质量标准4.1 主控项目4.1.1 暗敷在建筑物抹灰层内的引下线应有卡钉分段固定；明敷的引下线应平直、无急弯，与支架焊接处，油漆防腐且无遗漏。检查方法：检查隐蔽工程记录和观察检查4.1.2 变压器室、高低压开关柜室内的接地干线应有不少于2处与接地装置引出干线连接。4.1.3 当利用金属构件、金属管道做接地线时，应在构件或管道与接地干线间焊接金属跨接线。检查方法：观察检查4.2 一般项目4.2.1 明敷避雷引下线及室内接地干线的支持件间距应均匀，水平直线部分0.5～1.5m；垂直直线部分1.5～3m；弯曲部分0.3～0.5m。检查方法：观察和实测检查。4.2.2 接地线在穿越墙壁、楼板和地坪处应加套钢管或其他坚固的保护套管，钢套管应与接地线做电气连通。检查方法：观察检查4.2.3 变配电室内明敷接地干线应符合下列规定：4.2.3.1 便于检查，敷设位置不妨碍设备的拆卸与检修；4.2.3.2 当沿建筑物墙壁水平敷设时，距地面高度250～300mm;与建筑物 墙壁间的间隙10～15mm；检查方法：实测检查4.2.3.3 当接地线跨越建筑物变形缝时，设补偿设置；检查方法：观察检查4.2.3.4 接地线表面沿长度方向，每段15～100mm，分别涂以黄色和绿色相间的条纹；检查方法：观察检查4.2.3.5 变压器室、高低压配电室的接地干线上应设置不少于2个供临时接地用的接线柱或接地螺栓。检查方法：观察检查4.2.4 配电间隔和静止补偿装置的栅栏门及变配电室金属门铰链处的接地连接，应采用编织铜线。变配电室的避雷器应用最短的接地线与接地干线连接。检查方法：观察检查4.2.5 设计要求接地的幕墙金属框架和建筑物的金属门窗，应就近与接地干线连接可靠，连接处不同金属间应有防电化腐蚀措施。检查方法：观察检查4.2.6 当电缆穿过零序电流互感器时，电缆头的接地线应通过零序电流互感器后接地；由电缆头至穿过零序电流互感器的一段电缆金属护层和接地线应对地绝缘。检查方法：观察检查4.2.7 避雷引下线的保护管固定牢固可靠，断接卡子设置便于检测，接触面镀锌或镀锡完整，螺栓等坚固件齐全。防腐均匀，无污染建筑物。检查方法：观察检查。4.3 特殊工序或关键控制点的控制表4.3 特殊工序或关键控制点的控制    序号   特殊工序/关键控制点   主要控制方法     1   引下线、接地干线材质及规格核对    检查材质出厂证明等与，图纸设计相符     2   引下线、接地干线敷设   双面焊接，搭接倍数符合施工规范要求    4.4 质量记录4.4.1 镀锌钢材、铜材材质证明及产品出厂合格证。4.4.2 防雷及接地施工预检、自检、隐检记录齐全。4.4.3 设计变更洽商记、竣工图。5 应注意的质量问题5.0.1 利用主筋作引下线时，每条引下线不得少于2根主筋。5.0.2 引下线的固定支点间距离不应大于2m，敷设引下线时应保持一定松紧度，引下线应躲开建筑物的出入口和行人较易接触到的地点，以免发生危险。5.0.3 按地干线穿墙时，应加套管保护，跨越伸缩缝时，应做煨弯补偿。5.0.4 明敷设接地干线敷设应平直，水平度与垂直度允许偏差2/1000，但全长不超过10mm.5.0.5 转弯处接地干线弯曲半径不得小于扁钢厚度的2倍。6 成品保护6.1 避雷引下线安装：安装保护管时，注意保护好土建结构及装修面。6.2 变配电室接地干线敷设：6.2.1 电气施工时不得砸碰及弄脏墙面。6.2.2 喷浆前必须预先将接地干线纸包扎好。6.2.3 搬运物件时不得砸坏接地干线。6.2.4 焊接时注意保护墙面措施。7 职业健康安全与环境管理7.1 施工过程危害辨识及控制措施表7.1 施工过程危害辨识及控制措施    序号   主要作业活动   危险源   主要控制措施     1   高空作业   坠落 坠物   戴安全带   注：表中内容仅供参考，现场应根据实际情况重新辨识7.2 环境因素辨识及控制措施表7.2 环境因素辨识及控制措施    序号   主要作业活动   环境因素   控制措施     1   油漆作业   有毒有害气体挥发有毒有害废弃   有毒有害废弃物分类管理，作业结束后及时回收包装材料     2   引下线、干线安装   固体废弃物   定点放置、定时清理   注：表中内容仅供参考，现场应根据实际情况重新辨识</text><keywords>避雷引线,变电室接地干线</keywords><category>资讯</category><author>变电室接地干线</author><source>避雷引线</source><pubDate>2010-10-29 10:02</pubDate></item><item><title>独立架空地线</title><link>http://www.bileita.com/news/17.htm</link><description>独立架空地线：它是以在被保护物的上方适当的距离处所设置架线的导线作为受雷部分，而且是离开被保护物而独立设置的避雷设备。</description><text></text><keywords>独立架空地线</keywords><category>资讯</category><author>架空地线</author><source>架空地线</source><pubDate>2010-10-29 09:13</pubDate></item><item><title>避雷针受雷部定义</title><link>http://www.bileita.com/news/16.htm</link><description>避雷针受雷部定义：它是为遭受雷击所用的金属体。其中，除突针部、上粱导体及网罩的网眼状导体之外，还包括有直接遭受雷击所用的栏杆、篱笆及水槽等建筑物所附属的金属体</description><text></text><keywords>避雷针,避雷针受雷部</keywords><category>资讯</category><author>避雷针</author><source>避雷塔</source><pubDate>2010-10-29 09:12</pubDate></item><item><title>避雷针含义</title><link>http://www.bileita.com/news/15.htm</link><description>避雷针是由受雷部、避雷导线及接地极等组成的避雷用设备的总称。其目的是为了防止因雷击而发生的火灾、破损或对人畜的伤害。防雷装置由接闪器、引下线、接地装置、过电压保护器及其它连接导体组成</description><text></text><keywords>避雷针,含义</keywords><category>资讯</category><author>避雷针</author><source>避雷塔</source><pubDate>2010-10-29 09:11</pubDate></item><item><title>钢管避雷塔</title><link>http://www.bileita.com/news/14.htm</link><description>钢管避雷塔采用钢管作为塔柱材料,风荷载系数小,抗风能力强,避雷塔是塔柱采用外法兰盘连接,螺栓受拉,不易破坏,降低维护成本塔柱正三角型布置,节约钢材,跟开小,占地面积小</description><text>钢管避雷塔采用钢管作为塔柱材料,风荷载系数小,抗风能力强,避雷塔是塔柱采用外法兰盘连接,螺栓受拉,不易破坏,降低维护成本塔柱正三角型布置,节约钢材,跟开小,占地面积小,节约土地资源,选址便利避雷塔塔身自重轻,运输和安装便捷,建设工期短，避雷塔塔型随风荷载曲线变化设计,线条流畅,遇罕遇风灾不易倒塌,减少人畜伤亡；设计符合国家钢结构设计规范和塔桅设计规程,避雷塔结构安全可靠。</text><keywords>钢管避雷塔</keywords><category>资讯</category><author>钢管避雷塔</author><source>避雷塔</source><pubDate>2010-10-21 09:09</pubDate></item><item><title>烟筒塔</title><link>http://www.bileita.com/tieta/yantongta.htm</link><description>烟筒塔是指烟筒支撑塔架、废气排放塔、烟囱辅助支撑塔等..</description><text>烟筒塔1 烟筒塔2</text><image>http://www.bileita.com/up_files/yantongta1.jpg</image><keywords>烟筒塔,</keywords><category>铁塔产品列表</category><author>烟筒塔</author><source>烟筒塔</source><pubDate>2010-10-19 12:44</pubDate></item><item><title>风力发电塔</title><link>http://www.bileita.com/tieta/fadianta.htm</link><description>风力发电塔架及转动机构不仅要承受机组的重力,更大的是承受风所产生侧向力.这个力作用在塔架及转达机构上所产生的上下的拉压应力更大于机组的重力.</description><text>风力发电塔1 风力发电塔2       风力发电塔3 风力发电塔4       风力发电塔5 风力发电塔6</text><image>http://www.bileita.com/up_files/fadianta1.jpg</image><keywords>风力发电塔架,风力发电塔</keywords><category>铁塔产品列表</category><author>风力发电塔</author><source>风力发电塔</source><pubDate>2010-10-19 12:42</pubDate></item><item><title>仿生塔</title><link>http://www.bileita.com/tieta/fangshengta.htm</link><description>仿生塔</description><text>仿生塔1 仿生塔2       仿生塔3 仿生塔4      仿生塔5</text><image>http://www.bileita.com/up_files/fangshengta1.jpg</image><keywords>仿生塔</keywords><category>铁塔产品列表</category><author>仿生塔</author><source>仿生塔</source><pubDate>2010-10-19 12:29</pubDate></item><item><title>庆祝本站改版</title><link>http://www.bileita.com/news/11.htm</link><description>庆祝本站改版</description><text></text><keywords>庆祝本站改版</keywords><category>资讯</category><author>避雷铁塔</author><source>避雷塔</source><pubDate>2010-10-17 13:26</pubDate></item><item><title>烟筒塔_风力发电塔架</title><link>http://www.bileita.com/tieta/yantongta.htm</link><description>烟筒塔是指烟筒支撑塔架、废气排放塔、烟囱辅助支撑塔等.风力发电塔架及转动机构不仅要承受机组的重力,更大的是承受风所产生侧向力.</description><text>风力发电塔架及转动机构不仅要承受机组的重力,更大的是承受风所产生侧向力.这个力作用在塔架及转达机构上所产生的上下的拉压应力更大于机组的重力.所以塔架的强度,转动机构的强度无形中不得不提高数倍.而侧向力作用在塔架上所以会产生这么大的拉压应力是因为塔体的结构所造成的.(塔体的高和塔身的直径比很大,可达十倍,故造成了侧向力成十倍的增长而作用于塔身及转动机构.)同样,塔基也是.为了平衡侧向的风力,塔基的直径数倍至十倍的小于塔高,故塔基的重量得数倍至十倍的大于侧向风力.       烟筒塔1 烟筒塔2       风力发电塔架1 风力发电塔架2</text><image>http://www.bileita.com/up_files/yantongta1.jpg</image><keywords>烟筒塔,风力发电塔架</keywords><category>铁塔产品列表</category><author>风力发电塔架</author><source>烟筒塔</source><pubDate>2010-10-16 07:28</pubDate></item><item><title>训练塔_消防训练塔_训练塔要求</title><link>http://www.bileita.com/tieta/xunlianta.htm</link><description>训练塔应符合下列要求:一,训练塔宜设在靠近训练场尽端的部位;消防训练塔设计原则,消防训练塔设计依据,消防训练塔设计宗旨 电话:0318-7151369</description><text>消防训练塔设计宗旨：科学、方便适用消防训练塔设计依据：参照国家相关标准，设计并制作安装消防训练塔。根据（1983年3月　公安部发布　1981年10月1日起实行）消防站建筑设计标准《GMJ1--81》之第六章　建设消防训练塔的要求及制作标准附：第6.0.1条　消防站内应设置训练塔，其正面应设有长度不小于35米的跑道。　训练塔应符合下列要求： 一、训练塔宜设在靠近训练场尽端的部位； 二、训练塔层数应不少于四层，高层建筑物较多的城市，层数可适当增加； 三、训练塔正面的窗口每层不少于两个，窗间墙的宽度为1.0米；四、训练塔窗口的尺寸为1.2米1.8米，窗口距离塔边不得小于0.65米，窗台宽为0.4米（突出塔壁5厘米），每层窗台距该层地面的高度为0.8米，层高为3.5米，并应设有净宽不小于0.7米的内楼梯；五、在训练塔每层内侧应设置不小于1.5 米宽的平台，顶层应设置楼板； 六、训练塔宜设置室外消防梯。消防梯应通至塔顶，并宜离地面 3 米高处设起，宽度不宜小于50厘米。）消防训练塔产品说明：多功能消防训练塔，主要由（1）模拟窗、（2）楼层隔板、（3）后骨架、（4）了望、指挥平台骨架及主体钢结构框架等组成。在塔体前端部位设有八个模拟窗（根据需要定做几层几窗口），在上、下相邻的模拟窗之间设有楼层隔板（钢板）。２，在塔体后部下方设有与模拟窗相对应的后骨架。３，模拟窗与楼层隔板以及后骨架及主体框架相互之间用螺栓连接为一体，4，层与层之间均有安全楼梯连接。5，塔体上部装有了望、指挥平台。6，根据需要可安装测风仪、凉水带架和警报器等。7，根据需要，在消防训练塔旁边可制作模拟消防训练井。8，消防训练塔设备同时还配备消防专用滑轮、滑竿、模拟墙等附属设施。本训练塔结构科学、操作安全、使用方便，产品防腐处理热镀锌或热喷涂处理，50年无需维护，安全可靠。具有消防训练、了望、测风、报警等多种功能。同时便于指挥长随时掌握消防官兵的动作要领。是目前武警消防官兵消防训练实战演习之必备设备。同时替代了过去砖混结构消防楼的历史。消防训练塔做为广大消防官兵的练习设备，关系到战士们的人身安全，所以在选择生产厂家时，一定要选择经验丰富的厂家，战士们军事过硬，战士们所用的设备质量更要过硬。        消防训练塔1 消防训练塔2 消防训练塔3</text><image>http://www.bileita.com/up_files/image/Article/2010/09/19/37398141.jpg</image><keywords>训练塔,消防训练塔,</keywords><category>铁塔产品列表</category><author>消防训练塔</author><source>训练塔</source><pubDate>2010-09-19 10:23</pubDate></item><item><title>拉线塔_电力拉线塔</title><link>http://www.bileita.com/tieta/laxianta.htm</link><description>拉线塔(电力拉线塔)外观新颖,受力合理,塔体重量轻,施工简便周期短,是一种性能良好,经济实用的通信塔型,特别适用于城市及风景区等地.电话:0318-7151369</description><text>电力拉线塔1 电力拉线塔2 电力拉线塔3        电力拉线塔4 电力拉线塔5 电力拉线塔6</text><image>http://www.bileita.com/up_files/image/Article/2010/09/19/37218021.gif</image><keywords>拉线塔,电力拉线塔,</keywords><category>铁塔产品列表</category><author>电力拉线塔</author><source>拉线塔</source><pubDate>2010-09-19 10:20</pubDate></item><item><title>瞭望塔_了望塔</title><link>http://www.bileita.com/tieta/liaowanta.htm</link><description>瞭望塔(了望塔)暨森林防火监控塔由塔体、平台、塔楼、爬梯等组成，结构紧凑，经久耐用，是理想的火情监控，登高眺望，监视指挥工作台。电话:0318-7151369</description><text>瞭望塔1 瞭望塔2 瞭望塔3        瞭望塔4 瞭望塔5 瞭望塔6</text><image>http://www.bileita.com/up_files/image/Article/2010/09/19/37003131.jpg</image><keywords>瞭望塔,了望塔,</keywords><category>铁塔产品列表</category><author>了望塔</author><source>瞭望塔</source><pubDate>2010-09-19 10:16</pubDate></item><item><title>测风塔_测风塔功能_测风塔优点</title><link>http://www.bileita.com/tieta/cefengta.htm</link><description>测风塔由塔段,钢绞线,绝缘子,地锚,测风仪支架等钢构件组成.测风塔功能:环境监测,为测风仪器的安装做支撑.测风塔优点:风荷载系数小,抗风能力强.电话:0318-7151369</description><text>测风塔由塔段、钢绞线、绝缘子、地锚、测风仪支架等钢构件组成，并经热镀锌防腐或者除锈喷漆等防腐工艺处理，结构精密，塔体稳定.测风塔一般自重较轻，跨度小，都采用钢绞线加固方式，所以又叫拉线塔。测风塔功能：环境监测，为测风仪器的安装做支撑。测风塔适用单位：发电厂前期规划/海岛测风/海洋气象环境监测等部门。测风塔优点：风荷载系数小，抗风能力强.塔柱采用外法兰盘连接，螺栓受拉，不易破坏，钢绞线加固。塔柱正三角型布置,节约钢材,跟开小，占地面积小，节约土地资源，选址便利.塔身自重轻，运输和安装便捷、建设工期短,塔型随风荷载曲线变化设计，线流畅，遇罕遇风灾不易倒塌，减少人畜伤亡.设计符合国家钢结构设计规范和塔桅设计规程，结构安全可靠。抗损能力：风10级/地震6级防雷处理：配备优质避雷针加避雷带接地处理。高度：10米以上设计重量：〉1吨（具体重量根据地域而定，西部地区，沿海多风区与中部地区略有差异。）材质：Q235-Q345圆钢防腐处理：热渡锌防腐处理/冷渡锌防腐/油漆粉刷材料产地：宝钢/首钢/邯钢/唐钢等有效使用期：30年以上生产周期：自合同签订日起7个工作日生产完毕，如有特殊工艺要求，工期适当顺延。售后服务：10年免费上门维修，终身保修。        测风塔1 测风塔2 测风塔3        测风塔4 测风塔5 测风塔6</text><image>http://www.bileita.com/up_files/image/Article/2010/09/19/36757351.jpg</image><keywords>测风塔,测风塔功能,测风塔优点,</keywords><category>铁塔产品列表</category><author>测风塔功能</author><source>测风塔</source><pubDate>2010-09-19 10:12</pubDate></item><item><title>微波塔_微波铁塔_微波通信铁塔</title><link>http://www.bileita.com/tieta/weibota.htm</link><description>微波塔又称为微波铁塔,微波通信铁塔,多建于地面,楼顶,山顶.微波塔承风能力强,塔架多采用角钢材料辅以钢板材料,也可全部采用钢管材料组成 电话:0318-7151369</description><text>主要功能:支持电视信号发射.适用单位:各省市自治区广播电视部门        微波塔1 微波塔2 微波塔3        微波塔4 微波塔5 微波塔6</text><image>http://www.bileita.com/up_files/image/Article/2010/09/19/36501551.jpg</image><keywords>微波塔,微波铁塔,微波通信铁塔,</keywords><category>铁塔产品列表</category><author>微波铁塔</author><source>微波塔</source><pubDate>2010-09-19 10:08</pubDate></item><item><title>电视塔_广播电视塔_广播电视铁塔_电视铁塔</title><link>http://www.bileita.com/tieta/dianshita.htm</link><description>电视塔,广播电视铁塔立面廓线通常采用多折线型,既美观又能使基础受力小.广播电视铁塔腹杆形状有单斜杆式,十字交叉式,菱形,K再分式等几种.电话:0318-7151369</description><text>广播电视铁塔上设置用于工艺、燎望等用途的平台。其层次、数目与布置高度需根据使用要求确定。平台形状视塔身截面而定，平台结构的构件一般都采用角钢、槽钢、工字钢等型钢制成，为了便于高空安装，构件之间先用焊接连接成吊装单元，各单元之间用螺栓连接。       电视塔1 电视塔2       电视塔3 电视塔4       电视塔5 电视塔6</text><image>http://www.bileita.com/up_files/dianshita1.jpg</image><keywords>电视塔,广播电视塔,广播电视铁塔,电视铁塔,</keywords><category>铁塔产品列表</category><author>广播电视塔</author><source>电视塔</source><pubDate>2010-09-19 10:06</pubDate></item><item><title>装饰塔_装饰塔功能_装饰塔特点</title><link>http://www.bileita.com/tieta/zhuangshita.htm</link><description>装饰塔功能:装有普通避雷或高级专业产品避雷装置,并有美化夜景的功能.装饰塔特点:外型美观,耐腐蚀,具有良好的导电通讯性能,设计合理制作精良,便于安装,维修,保养.</description><text>装饰塔特点：我厂设计制作的不锈钢塔，外型美观、耐腐蚀、具有良好的导电通讯性能，设计合理制作精良，塔体设有通道，便于安装、维修、保养。　塔的造型新颖别致，能与各种现代化建筑物相呼应，能增加建筑物的外形 美，提升建筑物整体形象。（1）.装饰件：工艺塔结构专用无缝钢管及专用不锈钢球，完全符合GB/T14975标准要求。抗腐蚀标准符合GB14975-94，设计使用寿命50 年。        装饰塔1 装饰塔2 装饰塔3        装饰塔4 装饰塔5 装饰塔6      工艺装饰塔</text><image>http://www.bileita.com/up_files/gongyita1.jpg</image><keywords>装饰塔,装饰塔功能,装饰塔特点,</keywords><category>铁塔产品列表</category><author>装饰塔功能</author><source>装饰塔</source><pubDate>2010-09-19 10:01</pubDate></item><item><title>通讯塔_通讯塔用途_通讯塔特点_通讯塔功能</title><link>http://www.bileita.com/tieta/tongxunta.htm</link><description>通讯塔功能:支持信号发射,为信号发射天线做支撑.通讯塔用途:移动,联通,交通卫星定位系统(GPS)等通讯部门.通讯塔特点:在现代通讯及广播电视信号发射塔工程建设当中....</description><text>通讯塔用途：移动/联通/交通卫星定位系统(GPS)等通讯部门。通讯塔特点：在现代通讯及广播电视信号发射塔工程建设当中，无论用户选择地平面或楼顶铁塔，均起到架高通讯天线，增加通讯或电视发射信号服务半径，达到理想的专业通讯效果.另外楼顶还起到大楼的防雷接地、航空警示及装点办公大楼的双重功效。采用四脚自立式结构，符合钢结构设计规范。抗损能力：风12级/地震8级高度：60米以上；重量：10吨以上防腐处理：热渡锌；材料产地：宝钢/首钢/邯钢/唐钢等有效使用期：100年以上；售后服务：20年免费维修，终身保修       通讯塔1 通讯塔2       通讯塔3 通讯塔4       通讯塔5 通讯塔6</text><image>http://www.bileita.com/up_files/tongxunta1.jpg</image><keywords>通讯塔,通讯塔用途,通讯塔特点,通讯塔功能,</keywords><category>铁塔产品列表</category><author>通讯塔用途</author><source>通讯塔</source><pubDate>2010-09-19 09:55</pubDate></item><item><title>避雷塔_工艺避雷塔_装饰避雷塔</title><link>http://www.bileita.com/tieta/bileita.htm</link><description>避雷塔采用钢管作为塔柱材料,风荷载系数小,抗风能力强,塔柱采用外法兰盘连接,螺栓受拉,不易破坏,降低维护成本,节约钢材,占地面积小,节约土地资源.电话:0318-7151369</description><text>避雷塔采用钢管作为塔柱材料,风荷载系数小,抗风能力强,塔柱采用外法兰盘连接,螺栓受拉,不易破坏,降低维护成本塔柱正三角型布置,节约钢材,跟开小,占地面积小,节约土地资源,选址便利塔身自重轻,运输和安装便捷,建设工期短塔型随风荷载曲线变化设计,线条流畅,遇罕遇风灾不易倒塌,减少人畜伤亡设计符合国家钢结构设计规范和塔桅设计规程,结构安全可靠. 　　钢管避雷塔：采用钢管作为塔柱材料,风荷载系数小,抗风能力强,避雷塔是塔柱采用外法兰盘连接,螺栓受拉,不易破坏,降低维护成本塔柱正三角型布置,节约钢材,跟开小,占地面积小,节约土地资源,选址便利避雷塔塔身自重轻,运输和安装便捷,建设工期短，避雷塔塔型随风荷载曲线变化设计,线条流畅,遇罕遇风灾不易倒塌,减少人畜伤亡；设计符合国家钢结构设计规范和塔桅设计规程,避雷塔结构安全可靠。　　角钢避雷塔：采用角钢作为塔柱材料，风荷载系数小,抗风能力强,避雷塔是塔柱采用外包铁,螺栓受拉,不易破坏,降低维护成本塔柱正三角型布置,节约钢材,跟开小,占地面积小,节约土地资源,选址便利避雷塔塔身自重轻,运输和安装便捷,建设工期短，避雷塔塔型随风荷载曲线变化设计,线条流畅,遇罕遇风灾不易倒塌,减少人畜伤亡；设计符合国家钢结构设计规范和塔桅设计规程,避雷塔结构安全可靠。　　圆钢避雷塔:采用圆钢作为塔柱材料，风荷载系数小,抗风能力强,避雷塔是塔体全部采用焊接连接,降低维护成本塔柱正三角型布置,节约钢材,跟开小,占地面积小,节约土地资源,选址便利避雷塔塔身自重轻,运输和安装便捷,建设工期短，避雷塔塔型线条流畅,遇罕遇风灾不易倒塌,减少人畜伤亡；设计符合国家钢结构设计规范和塔桅设计规程,避雷塔结构安全可靠。           避雷塔1 避雷塔2       避雷塔3 避雷塔4       避雷塔5 避雷塔6  避雷塔主要用于建筑物的避雷、电力举措措施避雷、及特种行业避雷。结构形式为钢制，其材料组成有圆钢、角钢、钢管等金属结构。产品防腐处理热镀锌处理，50年无需维护。投资小，广泛用于各行业。本公司根据国标出产的避雷塔。结构公道，造型美观，经久耐用，防腐时间长。是理想的避雷产品。</text><image>http://www.bileita.com/up_files/bileita1.jpg</image><keywords>避雷塔</keywords><category>铁塔产品列表</category><author>工艺避雷塔</author><source>避雷塔</source><pubDate>2010-09-18 12:00</pubDate></item></document>